Curve 47

Curve 47 R/T Specifications

Updated Nov 5, 2026

North Star Sensors Curve 47

R/T Specifications

°CResistance
Ratio
Rt / R25
NTC
(%/°C)
Point Matched
Resistance
Mfg. Tol.
Adder (±%)
Inter­changeable
T2A Code
±°C Tol.
-5083.3790-7.427.70.65
-4557.8828-7.186.20.60
-4040.6707-6.945.60.54
-3528.9074-6.725.10.49
-3020.7731-6.504.50.45
-2515.0850-6.304.00.39
-2011.0646-6.103.40.35
-158.19383-5.912.90.30
-106.12371-5.742.50.25
-54.61689-5.562.00.22
03.51020-5.401.60.20
52.69037-5.241.30.20
102.07803-5.091.00.20
151.61702-4.940.70.20
201.26728-4.800.30.20
251.00000-4.670.00.20
300.79430-4.540.30.20
350.63490-4.420.60.20
400.51059-4.300.90.20
450.41302-4.181.20.20
500.33598-4.071.40.20
550.27479-3.971.70.20
600.22593-3.871.90.20
650.18669-3.772.20.20
700.15502-3.672.40.20
750.12932-3.582.60.22
800.10837-3.492.80.25
850.09121-3.413.10.28
900.07709-3.323.30.32
950.06542-3.243.50.36
1000.05574-3.173.70.41
1050.04767-3.093.90.45
1100.04091-3.024.10.50
1150.03524-2.954.30.55
1200.03046-2.884.40.60
1250.02642-2.824.60.66
1300.02299-2.754.70.72
1350.02006-2.694.90.77
1400.01757-2.635.00.85
1450.01542-2.575.20.95
1500.01358-2.525.41.05

Column Heading Definitions:

Resistance Ratio – The ratio of the resistance at temperature “t” to the resistance at 25 °C. To determine the resistance of a thermistor at a temperature point other than 25 °C, multiply the given resistance ratio by the resistance at 25 °C.

NTC – The Negative Temperature Coefficient of resistance is the % change in resistance per change in temperature, expressed in units of −%/°C. To determine the approximate % resistance tolerance of a thermistor at a particular temperature, multiply the given NTC value by the temperature tolerance at that temperature.

Point Matched – For thermistors with a specified tolerance at a single temperature point, the manufacturing tolerance is used to determine the tolerance at other temperature points. Typically, thermistors are specified at 25 °C. To determine the resistance tolerance at another temperature point, add the manufacturing tolerance to the specified point matched tolerance. For example, a thermistor with a ±10 % resistance tolerance at 25 °C has a ±11.6 % tolerance at 0 °C. Point matched thermistors should typically not cycle or operate continuously above 105 °C.

Interchangeable T2A Code – An interchangeable tolerance means that a thermistor has a temperature tolerance specified over a temperature range. For example, a “T2A” code indicates a ±0.2 °C temperature tolerance from 0 °C to 70 °C. Typically, interchangeable thermistors should not cycle or operate continuously above their specified temperature range.

North Star Sensors, LLC · info@northstarsensors.com · www.northstarsensors.com

Updated 5-Nov-2026